Quality index monitoring and application evaluation of nucleic acid pooling detection mode in blood stations
Journal Title: Chinese Journal of Blood Transfusion - Year 2025, Vol 38, Issue 2
Abstract
[Objective] To explore the influencing factors of quality monitoring index on the nucleic acid pooling detection mode and continuously improve the detection quality of nucleic acid laboratory. [Methods] The quality monitoring indicators (NAT reactive rate, NAT resolution reactive rate, NAT invalid batch rate, NAT invalid result rate, equipment failure rate) and causes of invalidity in our laboratory from January 1, 2020 to December 31, 2022 were retrospectively analyzed. The quality monitoring indicators of the laboratory during 2020 to 2022 were compared longitudinally. The quality monitoring indicators of the laboratory in 2022 were compared horizontally with the overall level in Shandong for the same period to find the differences. [Results] From 2020 to 2022, a total of 218 686 samples were detected, the NAT reactive rate was 0.15‰ (32 samples in total), the resolution reactive rate was 39.02%, the invalid batch rate was 1.06%, the invalid result rate was 1.18%, and the equipment failure rate was 3.58%. There were no differences in the NAT reactive rate, NAT resolution reactive rate and NAT invalid batch rate among different years (P>0.05), but there were differences in the invalid result rate (P<0.05). Equipment failure was the main cause of invalid results (56.53%). Compared with other laboratories in Shandong, there were differences in the NAT reactive rate and invalid result rate (P<0.05). There were differences in the reaction rate, resolution rate and invalid result rate among different reagents (P<0.05). Compared with other two laboratories using the same manufacturer's reagent, there were differences in the reactive rate and invalid result rate (P<0.05), but no difference in the resolution rate and invalid batch rate (P>0.05). [Conclusion] Establishing quality indexes for process control and regular analysis can timely detect potential risks in laboratory operation. The use of quality indicators to implement self-comparison and inter-laboratory comparison can help the laboratory systematically and scientifically evaluate its own operating status and formulate corresponding quality management strategies, thereby improving the laboratory's testing capacity and ensure the safety of blood use.
Authors and Affiliations
Fei DONG, Yang LIU, Guoliang DONG, Weiwei ZHAI, Weimin LIU, Xuemei LI
Blood transfusion adverse event management system: construction and application
Objective To establish a blood transfusion adverse event management system and apply it to adverse events management, so as to enhance the ability to identify and process reports as well as prevent adverse events. Method...
Autologous blood transfusion during heart valve replacement surgery: a retrospective study
Objective To retrospectively analyze the indexes of autologous blood transfusion during heart valve replacement, in order to provide reference for allogeneic blood transfusion during heart valve replacement surgery under...
Effect of MAP on preservation quality of deglycerolized red blood cells
Objective To observe the effect of deglycerolized red blood cells suspended in MAP on preservation and explore the most effective preservation method. Methods Concentrated red blood cells were prepared by centrifuging 40...
Application of monocyte monolayer assay on hemolytic disease of fetus and newborn caused by IgG anti-M
Objective To elucidate the prediction ability of monocyte monolayer assay(MMA) used in hemolytic disease of fetus and newborn(HDFN) caused by IgG anti-M. Methods Plasma from eight pregnant women containing IgG anti-M wer...
The introduction to and inspiration from haematological management of major haemorrhage: a British Society for Haematology guideline
Evidenced based and practical guidelines have important role in the decrease of mobility and mortality of the patients with major haemorrhage. Recently, British Society for Haematology updated a guideline on haematologic...