Radiological follow up of volar locking plating of distal radius fracture
Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 3
Abstract
Introduction: Fracture of the distal end radius constitutes one of the most common skeletal injuries treated by an orthopaedic surgeon. This study was aimed to assess the clinical and radiological outcome of the intra-articular fracture distal end radius treated with variable angle mini-fragment volar plate fixation. Methodology: In the prospective study, patients presenting with distal end radius fracture and then operated with mini-fragment volar locking distal radius plating were included. All patients were evaluated by a senior orthopaedic surgeon at 3, 6 and 24 weeks post-operatively, during which patients underwent a physical examination of the wrist and forearm motion and grip strength, followed by radiological evaluation. Range of movement and complications were noted for all patients at each follow up visit. Results: 64% of the patients were below the age of 40 years. Approximately three fourths of all patients were classified as Frykmann distal radius fracture type VIII. The mean radial inclination, length and tilt were maintained throughout the follow up period. The range of dorsiflexion, palmarflexion, supination and pronation improved significantly at each follow up. 8% had superficial skin infection, 4% had serous discharge and loss of reduction each and 84% did not report any complications. Conclusions: Primary volar mini-fragment variable angle plate fixation of freshly displaced distal radius fracture provides complete union, with immediate mobilization, better functional outcomes, minimizes chances of delayed/malunion.
Authors and Affiliations
Dr. Amlan Mohapatra, Dr. Karthikraj Kuberakani
Design of anatomically locked plate for posterior malleolus by computer aided technique
Objective: To use computer aided technology to design anatomic plate for the posterior ankle by software Mimics, CT and 3D printing. Methods: The CT data of 20 normal ankles were imported into software Mimics in dicom fo...
Functional and radiological outcome in tibial condylar fracture with posteromedial fragment fixed with buttress plate
Background: The posteromedial fragment of tibial plateau fracture remains unrecognized for a long time, leading to inadequate fixation with conventional methods and resulting in early varus collapse. So our study is to o...
Results of locking compression plate in the management of fracture distal end of femur in adults
Introduction: The use of locking compression plate in fractures of distal femur in our study seems to be associated with a good functional outcome and early recovery. The DF-LCP is a good implant to use for fractures of...
Role of image intensified fluoroscopy guided closed vertebral biopsy in perplexed lesions of spine: A retrospective study
Background: The percutaneous image-guided procedure is faster and more cost-effective and has an overall lower risk of complications. Despite considering image intensified fluoroscopy guided biopsy of spine as one of the...
Osteochondroma of talus
Osteochondroma or exostosis is the most common benign bone tumor, and occurring frequently around knee and proximal humerus. It rarely affects pelvis, vertebra, spine. Osteochondroma of talus is a very rare [1]. We repor...