RELIABILITY AND MINIMAL DETECTABLE CHANGE OF SIT-TO-STAND KINEMATICS AND KINETICS IN TYPICAL CHILDREN

Journal Title: Human Movement - Year 2018, Vol 19, Issue 3

Abstract

Purpose. The study aimed to determine the within- and between-session reliabilities as well as the minimal detectable change (MDC) of generally used temporal, kinematic, and kinetic parameters during the sit-to-stand (STS) task in typical children. Methods. The study involved 10 typical children (9.8 ± 1.6 years old). Motion analysis and force plate systems were used to collect markers for 3-dimensional trajectories in space and measure the ground reaction force. The total of 29 reflective markers were placed on each participant’s body in accordance with the Helen Hays marker set model by 1 rater on 2 separate days within the span of 1 week. Each subject was asked to perform an STS task 3 times from a height-adjustable chair. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and MDC for temporal, kinematic, and kinetic parameters were calculated within and between sessions. Results. The results indicated that the temporal parameters achieved excellent (ICC > 0.75), the kinematic parameters presented poor to excellent (0.232 < ICC < 0.997), and the kinetic parameters showed fair to excellent (0.635 < ICC < 0.977) reliabilities in both within- and between-session analyses. The SEM of most kinematic parameters was less than 2° both within and between sessions. In addition, the MDC values for between sessions ranged 1.25–12.64°. Conclusions. The findings support the reliability of using 3-dimensional motion analysis and force plate systems for measuring temporal, kinematic, and kinetic parameters for STS tasks in typical children. Key words: reliability, minimal detectable change, children, sit-to-stand, kinematics, kinetics

Authors and Affiliations

DUANGPORN SURIYAAMARIT, SUJITRA BOONYONG

Keywords

Related Articles

COMPLEMENT PROTEINS (C1EST, C4, C6), CIRCULATING IMMUNE COMPLEXES AND THE REPEATED BOUT EFFECT

Purpose. To determine if the complement system is activated following strenuous eccentrically-biased exercise. Secondly, to determine if complement activation is attenuated (repeated bout effect) following a second bout...

The differences between medalists and non-medalists at the 2008 Olympic Games Taekwondo Tournament

Purpose. To establish the differences in some morphological characteristics and competitive efficacy parameters between the medal winners and other competitors in male and female competitions at the Olympic taekwondo tou...

The impact of training on the 500 m rowing ergometer time and an assessment of the applied test’s relevancy

Purpose. The purpose of the conducted research was to determine the impact of training on the time spent covering a distance of 500 m on a rowing ergometer as well as an examination of the representativeness of the adopt...

HIGH AND LOW IMPACT AEROBIC EXERCISE AS A METHOD OF EARLY PREVENTION OF HYPERCHOLESTEROLAEMIA DEVELOPMENT AMONG YOUNG WOMEN

Purpose. Hypercholesterolaemia is a highly prevalent condition that has major health- and cost-related implications for the society. Aerobic-type exercise improves lipoprotein-lipid profiles, cardiorespiratory fitness an...

Subjective assessment of sports success in wheelchair rugby – proposal of a new research tool

Purpose. The main purpose of this study was to design and perform a preliminary psychometric analysis of a measure in the subjective assessment of sports success in wheelchair rugby (WR). An additional objective of this...

Download PDF file
  • EP ID EP333015
  • DOI 10.5114/hm.2018.76079
  • Views 101
  • Downloads 0

How To Cite

DUANGPORN SURIYAAMARIT, SUJITRA BOONYONG (2018). RELIABILITY AND MINIMAL DETECTABLE CHANGE OF SIT-TO-STAND KINEMATICS AND KINETICS IN TYPICAL CHILDREN. Human Movement, 19(3), 48-54. https://www.europub.co.uk/articles/-A-333015