Reliability Assessment of Electrical Energy Distribution System – A Case Study of Port Harcourt Distribution Network

Abstract

This Paper Presents the Reliability Assessment of Electrical Energy Distribution System in Port Harcourt using the Analytical Technique and ETAP software as the simulation tool to run the reliability assessment of the System. The analysis was carried out using 2014 and 2015 historical data of Secretariat, Silver Bird, Water Works, UST and School of Nursing Injection Substations obtained from the Port Harcourt Electricity Distribution Company[PHEDC]. The results of the analysis revealed that Secretariat Injection Substation is the most reliable in the network when compared to the other four substations as it recorded system indices of ASAI: 99.90, SAIFI: 0.877, SAIDI: 8.11, CAIDI: 9.25 in 2014 and ASAI: 99.91, SAIFI: 0.873, SAIDI: 8.13, CAIDI: 9.14 in 2015. However, the overall reliability indices of the five substations under review as obtained from the analysis, revealed that the reliability of the distribution system is far below the set benchmark. System re-configuration and introduction of Photovoltaic Systems to re- supply interrupted loads at a shorter time are therefore recommended.

Authors and Affiliations

Fabian C. Oreke, D. C Idoniboyeobu

Keywords

Related Articles

Survey on Techniques for Enhancing the Quality of Satellite Images

Satellite images are used in many fields of research (eminence factors in images comes from its resolution) and in many applications such as astronomy, geographical information systems & geosciences studies. Satellite i...

Experimental Study on Recycled Concrete Using PP Fiber

In this thesis we have discuss about the use of Recycled Aggregate (RA) in the concrete and the effects on its Compressive Strength and Split Tensile Strength by progressively replacing the natural aggregate (NA) with r...

Analysis of Low Leakage Architecture of SRAM 8x1 Using Leakage Power Reduction Technique in Different Technology

as the size of ic’s is becoming small, day by day the demand of high density vlsi circuits has been increasing .the supply voltage reduction is necessary to reduce the active power. By lowering the supply voltage it is...

Thermodynamic Analysis of Combined ORC-VCR System Using Low Grade Thermal Energy

The world is facing energy and environmental challenges due to population growth and economy development. The utilization of renewable energy can significantly contribute to reduction in consumption of conventional ener...

IoT based Smart Home automation with security surveillance

The home automation systems have seen large scale transformation in recent years, beginning from panic switches to send fixed messages to specified recipients during emergency, remote controlled switches for machines, s...

Download PDF file
  • EP ID EP24449
  • DOI -
  • Views 262
  • Downloads 10

How To Cite

Fabian C. Oreke, D. C Idoniboyeobu (2017). Reliability Assessment of Electrical Energy Distribution System – A Case Study of Port Harcourt Distribution Network. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(6), -. https://www.europub.co.uk/articles/-A-24449