Response to Neutrons and γ-rays of Two Liquid Scintillators

Abstract

UltimaGoldTM AB and OptiphaseTrisafe are two liquid scintillators made by Perkin Elmer and EG & G Company respectively. Both are commercially promoted as scintillation detectors for α and β particles. In this work, the responses to γ-rays and neutrons of UltimaGoldTM AB and OptiphaseTriSafe liquid scintillators, without and with reflector, have been measured aiming to use these scintillators as γ-rays and neutron detectors. Responses to γ-rays and neutrons were measured as pulse shape spectra in a multichannel analyzer. Scintillators were exposed to gamma rays produced by 137Cs, 54Mn, 22Na and 60Co sources. The response to neutrons was obtained with a 241AmBe neutron source that was measured to 25 and 50 cm from the scintillators. The pulse height spectra due to gamma rays are shifted to larger channels as the photon energy increases and these responses are different from the response due to neutrons. Thus, UltimaGoldTM AB and OptiphaseTrisafe can be used to detect γ-rays and neutrons.

Authors and Affiliations

Hector Rene Vega-Carrillo , Martha Isabel Escalona-Llaguno , Luis Hernandez-Adame , Sergio M. Sarmiento-Rosales , Claudia A. Márquez-Mata , Guillermo E. Campillo-Rivera , V. P. Singh , Teodoro Rivera-Montalvo , Segundo Agustin Martínez-Ovalle

Keywords

Related Articles

Determination of the Thermal Neutron Flux by Measuring Gamma Radiations with High and Low Resolution Detectors

Thermal neutron flux (Фth) of Americium-Beryllium (Am-Be) neutron source has been measured by adopting the foil activation method. The neutrons emitted from Am-Be source are used to activate the indium-115 (115In) foil....

Implementation of a Low Cost For Internal Dosimetry Radiological Survey of Ionization Radiation Exposed Workers In Nuclear Medicine Services

Because the nature of the routine activities carried on in nuclear medicine services, where several not sealed radioactive sources are used, the occupational personal exposed to ionization radiation (POE) is exposed to b...

Radon in Workplaces the Urgent Need of New Measurements and Devices

The existing passive radon monitors, their relative calibration facilities together with the past intercomparison exercises have been mission-oriented towards radon measurements in dwellings. These monitors have been suc...

Nuclear Tracks Morphology Study Using Raman Methodology

In this work, a new methodology for rendering profiles of etched nuclear tracks is presented, using confocal micro-Raman spectrometry instrumentation. The precise profile of etched nuclear tracks with normal and/ or angu...

Evolution of Shapes and Search for Shape Coexistence in Sd-Shell Nuclei

A detailed and systematic study has been performed using state-dependent Relativistic Mean-Field plus BCS (RMF+BCS) approach to investigate shape evolution for even-even isotopes of Ne, Mg, Si and S. We perform quadrupol...

Download PDF file
  • EP ID EP566986
  • DOI 10.15415/jnp.2019.6.02.161-169
  • Views 333
  • Downloads 0

How To Cite

Hector Rene Vega-Carrillo, Martha Isabel Escalona-Llaguno, Luis Hernandez-Adame, Sergio M. Sarmiento-Rosales, Claudia A. Márquez-Mata, Guillermo E. Campillo-Rivera, V. P. Singh, Teodoro Rivera-Montalvo, Segundo Agustin Martínez-Ovalle (2019). Response to Neutrons and γ-rays of Two Liquid Scintillators. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(2), 161-169. https://www.europub.co.uk/articles/-A-566986