ROTATION CAPACITY OF BOLTED FLUSH END-PLATE STIFFENED BEAM-TO-COLUMN CONNECTION

Journal Title: Civil and Environmental Engineering Reports - Year 2017, Vol 2, Issue 25

Abstract

One of the flexibility parameters of semi-rigid joints is rotation capacity. Plastic rotation capacity is especially important in plastic design of framed structures. Current design codes, including Eurocode 3, do not posses procedures enabling designers to obtain value of rotation capacity. In the paper the calculation procedure of the rotation capacity for stiffened bolted flush end-plate beam-to-column connections has been proposed. Theory of experiment design was applied with the use of Hartley’s PS/DS-P:Ha3 plan. The analysis was performed with the use of finite element method (ANSYS), based on the numerical experiment plan. The determination of maximal rotation angle was carried out with the use of regression analysis. The main variables analyzed in parametric study were: pitch of the bolt “w” (120-180 mm), the distance between the bolt axis and the beam upper edge cg1 (50-90 mm) and the thickness of the end-plate tp (10-20 mm). Power function was proposed to describe available rotation capacity of the joint. Influence of the particular components on the rotation capacity was also investigated. In the paper a general procedure for determination of rotation capacity was proposed.

Authors and Affiliations

Krzysztof OSTROWSKI, Aleksander KOZŁOWSKI

Keywords

Related Articles

THEORETICAL AND EXPERIMENTAL ANALYSIS OF HEAT TRANSFER IN THE LAYERS OF ROAD PAVEMENT

A heat transfer problem for the road pavement system “layered plate – embankment – soil base” is formulated. There are suggested mathematical models in this work; they are realized with finite element analysis and design...

COOLING OF A PROCESSOR WITH THE USE OF A HEAT PUMP

In this paper the problem of cooling a component, in the interior of which heat is generated due to its work, was solved analytically. the problem of cooling of a processor with the use of a heat pump was solved based on...

TRIMBLE M3 1” AND SOUTH NTS-362R TOTAL STATION ANGLE MEASUREMENT ACCURACY ANALYSIS

The main purpose of this study was to obtain information about the actual precision of angle measurements with two instruments (Trimble M3 1 "and South NTS-362R), realizable in given measurement conditions. This object i...

ASCE HONOR FOR THE TCZEW BRIDGE IN POLAND

This note presents the background for the introduction of the quoted bridge, as the International Civil Engineering Landmark, on the list of the ASCE History and Heritage Program. The history and the key structural featu...

VALUE OF ANTIQUITY IN THE RESTORATION PROCESS OF THE ART NOUVEAU VILLA DUELFER IN BARLINEK

The value assigned to time-worn objects and buildings seems crucial to a conservator’s theoretical beliefs. The notion of antiquity is almost imprinted in the structure of the building itself, as well as in the concept o...

Download PDF file
  • EP ID EP243189
  • DOI -
  • Views 77
  • Downloads 0

How To Cite

Krzysztof OSTROWSKI, Aleksander KOZŁOWSKI (2017). ROTATION CAPACITY OF BOLTED FLUSH END-PLATE STIFFENED BEAM-TO-COLUMN CONNECTION. Civil and Environmental Engineering Reports, 2(25), 173-184. https://www.europub.co.uk/articles/-A-243189