Rotor Angle Stability Improvement of DFIG Using Grid Side and Rotor Side Converter Control

Abstract

Wind energy generation with Doubly Fed Induction Generator is dominant one in wind farms. High penetration of DFIG is creating more instability in rotor side and grid side. Applying a set of optimized control parameter, the stability can be further enhanced. In this paper variable load condition rotor angle stability of the DFIG is improved by Grid Side (GSC) and Rotor Side Converter (RSC) control. In DFIG, the frequency of the rotor excitation input, real and reactive powers are modified based on rotor speed and load variation. The simulation result shows the effectiveness and performance of the DFIG with GSCRSC converter control techniques.

Authors and Affiliations

Mathusoothanan. T, Dr. R. Karthik

Keywords

Related Articles

Motion Compensation Techniques Adopted In HEVC

High Efficiency Video Coding (HEVC) is currently being prepared as the newest video coding standard of the ITU-T Video Coding Experts Group and the ISO/IEC Moving Picture Experts Group. The main goal of the HEVC standar...

Recognition of American Sign Language Fingerspelling by Applying Matrix Matching Algorithm Using Leap Motion Controller Sensor

This paper presents the recognition of American Sign Language Fingerspelling by applying Matrix Matching algorithm using Leap Motion Controller Sensor. The study focused on the recognition of all the static and dynamic...

Bubble Deck

This paper proposes an approach for creating biaxial slabs using bubble deck. This approach avoids the limitations in hollow core slabs, lack of structural integrity, inflexibility and lack of architectural possibilitie...

A Kinetics Study of Solvent Effect on solventsolute interaction and mechanism of the Iondipolar reaction in an aquo-organic co solvent system

A kinetic study of solvolysis reaction of methyl salicylate in water-DMF solvent using different concentration of DMF (v/v) was made at four different temperatures i.e., 200 C, 250 C, 300 C, 350 C & 400 C. The rate of r...

Mechanical Properties of cementitious composite by using ZnO nanoparticles

The split tensile and the setting time of cement with different Concentration of ZnO Nanoparticles (0.5%, 0.1%, 1.5% , 2.0%,2.5% ,3% by weight) has been studied. the mechanical (flexural and split tensile) strength of t...

Download PDF file
  • EP ID EP21690
  • DOI -
  • Views 226
  • Downloads 3

How To Cite

Mathusoothanan. T, Dr. R. Karthik (2016). Rotor Angle Stability Improvement of DFIG Using Grid Side and Rotor Side Converter Control. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 4(3), -. https://www.europub.co.uk/articles/-A-21690