Sensitivity Modeling and Evaluation of Evapo-transpiration Effects on Flow Discharge of River Owena in Nigeria
Journal Title: Analele Universitatii "Eftimie Murgu" Resita. Fascicula de Inginerie - Year 2015, Vol 22, Issue 1
Abstract
Analysis of discharges, precipitation and temperature and some other meteorological-hydrological variables from 1996-2011 at the section of Owena River Basin. The evaluation, correlations, and the relationship between precipitation and discharge time series indicate a strong relationship. Minimum discharge values of 0.8 m3/s and 1.2 m3/s were observed in January and December and these values correspond to rainfall depth of 1.4 mm and 8.2 mm respectively. The average annual rainfall, river discharge were computed as 1,306.7 mm, 1,165 m3/s and mean temperature and evaporation of 31.1oC and 4.6 mm. Evapotranspiration computation using pan evaporation model overestimated the evapotranspiration values by 0.5 mm and 0.21 mm over IHACRES and CROPWAT model for the total period of 15-year. Integration of the simulation outputs would be veritable in creating realistic-robust water management system for domestic and agricultural applications.
Authors and Affiliations
P. O. Idogho, Olotu Yahaya
Statistical Analysis of the Results of Surface Treatment with Optical Pulses Applied to Parts of Metallic Powders
Within a wide range of theoretical and experimental research, the possibility of realizing a new method of superficial treatment of materials made of metallic powders and the validation of the results obtained after the...
On-line Identification of the DC motor Parameters by using Least Mean Square Recursive Method
The on-line least square parameters (electrical and mechanical) identification method of the separately DC motor is presented in this paper. The parameters of the DC machine are time dependent; therefore, for the DC driv...
The Quality Analysis of the Thermal Sprayed Deposited Layers by Electronically Microscopy
The analysis performed by electronically microscopy lead to obtain the experimental data under tabular form. A linear chemical quantitative analysis over a 228.87 μm length was made of on a microscopically image at 250x...
Aspects regarding the Calculation of the Dielectric Loss Angle Tangent between the Windings of a Rated 40 MVA Transformer
The paper aims to identify how to determine the dielectric loss angle tangent of the electric transformers from the transformer stations. Autors of the paper managed a case study on the dielectric established between hig...
New Aspects Concerning the CEUS Figures Identified at Ferrofluid Utilisation in Rotating Magnetic Field
Within the EMAD Research Center was initiated researches about CEUS figures obtained by exposing the content of a cylindrical container on the progressive action of the magnetic field produced by a special winding associ...