Simplified Method for Substation Grounding System Design

Abstract

This paper focused 230 66 kV, substation grounding system and calculation results of required parameters at location of Kalay region. The grounding system is essential to protect people working or walking in the vicinity of earthed facilities and equipments against the danger of electric shock. It provides the floor surface either assures an effective insulation from earth potential or effectively equipment to a close mesh grid. Calculations of grounding grid system in the substation area where the top soil layer resistivity is less than the bottom layer resistivity can be less the number of ground rod used in the grid because the value of Ground Potential Rise GPR is insignificantly different. To get desired parameters such as touch and step voltage criteria for safety, earth resistance, grid resistance, maximum grid current, minimum conductor size and electrode size, maximum fault current level and resistivity of soil are designed in detail consideration. Aye Myo Thant | Cho Cho Win | Thant Zaw Oo "Simplified Method for Substation Grounding System Design" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd26754.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/26754/simplified-method-for-substation-grounding-system-design/aye-myo-thant

Authors and Affiliations

Keywords

Related Articles

Antecedents of Functional Food Purchase Intention of Sri Lankan Consumers The Mediating Effect of Consumer Attitudes

“Functional Food” is food and food components which provide benefits beyond basic nutrition, and it includes a wide variety of food and food components believed to improve overall health and well being of people whic...

FTIR Spectra of Magnetic Charge Transfer Complexes of TEMPO Free Radical

The Fourier '“ transform infrared spectra of complexes of TEMPO free radical with organic acceptors like TCNE, DDQ, TCNQ, Chloranil has been studied. Some of them have ferro or antiferromagnetic properties at very low te...

Relationship between Banker and Customer

Customers are those who avail a service of any goods and services provided by the manufacturer or service provider with due consideration of money. In the same way the moment an individual opens an account with the banke...

A Situation Aware Navigation System

When emergencies happen, navigation services that guide people to exits while keeping them away from emergencies are critical in saving lives. To achieve timely emergency navigation, early and automatic detection of pote...

Tumors of Kidney

Kidney tumors, also known as renal tumors, are tumors, or growths, on or in the kidney. These growths can be benign or malignant cancerous . They may be discovered on medical imaging incidentally i.e. anincidentaloma , o...

Download PDF file
  • EP ID EP629998
  • DOI 10.31142/ijtsrd26754
  • Views 87
  • Downloads 0

How To Cite

(2019). Simplified Method for Substation Grounding System Design. International Journal of Trend in Scientific Research and Development, 3(5), 1798-1801. https://www.europub.co.uk/articles/-A-629998