Stereomicroscopic Evaluation of Radicular Dentinal Defects after Using EDTA Gel with Different Rotary Systems: An In-Vitro Study

Journal Title: Saudi Journal of Oral and Dental Research - Year 2016, Vol 1, Issue 3

Abstract

Abstract: The purpose of the present study was to study the occurrence of radicular dentinal defects after using EDTA gel during preparation of the root canal with ProTaper Universal (DentsplyMaillefer, Switzerland), HyFlex (Coltene- Whaledent, Allstetten, Switzerland), and ProTaper Next (DentsplyMaillefer) rotary instruments. Forty-eight single rooted premolars were selected. Twelve teeth were instrumented with hand files; another 12 teeth were instrumented with the ProTaper Universal system up to size F3 and the remaining 24 teeth were shaped with Hyflex CM 25/0.6 and ProTaper Next X3. EDTA gel was used during the root canal preparations of each tooth. After the completion of root canal instrumentation, the roots were sectioned at 3mm,6mm and 9mm followed by stereomicroscopic observation of the sections. The absence/presence of radicular dentinal defects was documented, and the data analysis was done with a chi-square test. The significance level was set at P = 0.05. The ProTaper Next and HyFlex CM instruments caused fewer cracks (33.33% and 50%) than the ProTaper Universal instrument (66.7%) (P < .05). However, there were no significant variances in radicular dentinal defects formation between the Hyflex CM and ProTaper Next groups (P > 0.05). Within the confines of this in vitro study, all of the instrumentation systems used induced radicular defects in the root dentin. The ProTaper Next and HyFlex instruments tended to cause fewer dentinal cracks compared with the ProTaper Universal instrument. Keywords: Radicular dentinal defects, EDTA gel, Hand Files, Niti Rotary instruments

Authors and Affiliations

Sadashiv Daokar, Syed Navid Ali, Arshia R. Baig

Keywords

Related Articles

Prevalence of Chronic Periodontitis and its associated risk indicators Among Saudi Nationals in Aljouf Province Kingdom of Saudi Arabia

Abstract:Chronic Periodontitis is considered to be common dental disease with high tooth mortality as well as morbidity. Reports from different places around the world showed a prevalence of severe periodontitis in aroun...

The Restoration of an Orbital Defect Using a Magnet Retained Silicone Prosthesis- A Case Report

Abstract:Rehabilitation of Maxillo-facial defects is a complex task, requiring an individualized approach and modification of existing techniques to suit the needs of each patient. A removable, suitably retained prosthes...

Supracrestal Gingival Tissue Measurements in Healthy Human Periodontium

Abstract:The objective of the study is to measure the dimensions of supracrestal gingival tissue in healthy human periodontium.In this study 30 dental students with clinically healthy periodontium were examined by doings...

Evaluation of Extra Coronal Axial Wall Taper Angle Preparation among Dental Students (Taibah University)

Evaluation of Extra Coronal Axial Wall Taper Angle Preparation among Dental Students (Taibah University) Abstract:The research report is used as a simple and precise method/ procedure of measuring and determining the con...

Gorlin Cyst or a Benign Odontogenic Tumor: A Diagnostic and Treatment Dialemma

Abstract:The Calcifying Odontogenic Cyst (COC) represents a heterogeneous group of lesions that exhibits a variety of clinicopathologic and behavioural features. Therefore a proper categorization of the cases is needed f...

Download PDF file
  • EP ID EP394095
  • DOI -
  • Views 87
  • Downloads 0

How To Cite

Sadashiv Daokar, Syed Navid Ali, Arshia R. Baig (2016). Stereomicroscopic Evaluation of Radicular Dentinal Defects after Using EDTA Gel with Different Rotary Systems: An In-Vitro Study. Saudi Journal of Oral and Dental Research, 1(3), 113-118. https://www.europub.co.uk/articles/-A-394095