Substation Earthing Design

Abstract

Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In any substation, a well-designed grounding plays an important role. Since absence of safe and effective grounding system can result in mal-operation or non-operation of control and protective devices, grounding system design deserves considerable attention for all the substations. There are two primary functions of a safe earthing system. Firstly, ensure that a person who is in the vicinity of earthed facilities during a fault is not exposed to the possibility of a fatal electrical shock. Secondly, provide a low impedance path to earth for currents occurring under normal and fault conditions.The earthing conductors, composing the grid and connections to all equipment and structures, must possess sufficient thermal capacity to pass the highest fault current for the required time.

Authors and Affiliations

Akshay Patil

Keywords

Related Articles

PSPICE Simulation For A Solar Panel To Understand Shading Effects

The present work is a study of the effects of partial shading on the performance of a PV module spatially on the maximum power point position. This search clarifies the mechanism of partial PV shading on a number of PV m...

Precision Control of Induction Motor Drive through Pressure Transducer

The variable frequency drives in various applications could save energy, cut costs and increase profit margins. A system with a feedback controller will attempt to drive the system to a state described by the input, such...

Thermal Energy Storage System Using Longitudinal Fins Arrangement (120˚ apart)

Solar power is a clean and sustainable energy as it is pollution free and environment friendly. This energy can be stored as thermal energy using latent heat storage system. The storage material used in our work is paraf...

Substation Earthing Design

Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In a...

Cuckoo Search Algorithm for Environmental/Economic Dispatch Problem

This paper proposes a new meta-heuristic search algorithm, called cuckoo search algorithm (CSA). The cuckoo search is an optimization algorithm based on the brood parasitism of cuckoo species by laying their eggs in the...

Download PDF file
  • EP ID EP389014
  • DOI 10.9790/1676-1201021217.
  • Views 156
  • Downloads 0

How To Cite

Akshay Patil (2017). Substation Earthing Design. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(1), 12-17. https://www.europub.co.uk/articles/-A-389014