The Analysis of Biphasic Short Circuit Regimes to Doubly-fed Induction Generators Connected to a Power System

Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2013, Vol 37, Issue 37

Abstract

The paper presents analysis of the biphasic short circuit regimes at the terminals of doubly fed induction generator connected to the national power system of the Republic of Moldova. Research related to connecting wind farms to the national electricity system have shown vulnerability related to the supply or consumption of reactive power especially in short circuit regimes with locking rotor inverter. Reactive power consumption asynchronous generator increases essentially under unbalanced and is related to increased rotor reactance about negative sequence currents. The biphasic short-circuit is the high degree of asymmetry 100% (U1/U2=1). Besides increasing the reactive component of current are increasing resulting critical current value. Under asymmetrical regimes because direct and reversed sequence components interaction appear dual-frequency pulses (100Hz) of active and reactive powers, dangerous mechanical couples due to resonance of mechanical parts.

Authors and Affiliations

Victor Gropa

Keywords

Related Articles

Circuit Breaker Test Equipment

Switching elements are present in low, medium and high voltage transport and distribution networks. Circuit breaker is a switch that automatically interrupts the flow of electric current if the current exceeds a specific...

DESIGN AND PERFORMANCES OF COUPLING PASSIVE FILTERS IN THREE-PHASE SHUNT ACTIVE POWER FILTERS

The passive interface filter represents the link between the power grid and the shunt active filter. The interface filter is used both to obtain a good dynamic of the compensating current and to limit the high frequency...

RESONANT SOURCE FOR THE SUPPLY OF ELECTRIC FIELD PROBE CALIBRATION SYSTEM AT FREQUENCIES BETWEEN 50Hz AND 50KHz

Electromagnetic environmental conditions checking and provision regarding long and short time human personal and occupational exposure is regulated by international standards. Generally, the human being is exposed mainly...

 The Synchronous Fundamental dq Frame Theory Application for the Active Filtering

 One of the methods that have been used for the analysis of three phase systems is the rotating fundamental dq frame. Although it was especially used for the analysis of three phase machines, because it is a time...

ELECTROMAGNETIC FIELD DISTRIBUTION IN VICINITY OF POWER LINES ABOVE REAL EARTH

A method for electromagnetic field components calculation in vicinity of power lines is presented. The electromagnetic field distribution of 2x110 kV power line, which is commonly used in Serbian electric power system, i...

Download PDF file
  • EP ID EP162405
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

Victor Gropa (2013). The Analysis of Biphasic Short Circuit Regimes to Doubly-fed Induction Generators Connected to a Power System. ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica, 37(37), 68-72. https://www.europub.co.uk/articles/-A-162405