The Explosion of Tanks Containing Compressed Flammable Gas as a Risk for Firefighters at Work

Journal Title: Safety & Fire Technology - Year 2017, Vol 48, Issue 48

Abstract

Aim: This article explores the levels of risks faced by firefighters associated with the explosion of tanks/cylinders containing compressed flammable gases during fires. Introduction: Explosions are among the causes of accidents during firefighting and rescue operations. The scale of this problem is reflected in the statistical data on the victims of incidents involving the explosion of industrial gases – the number of people injured in industrial-gas explosions between 2000 and 2014 was 945, including 84 rescuers, and the number of deaths was 48. As a result of economic growth, there are more and more containers with compressed gases, including tanks for alternative car fuels, being sold and transported. Therefore, explosions seem unavoidable, and their number is not likely to drop. Methodology: The risks associated with firefighting operations involving the risk of the explosion of tanks/cylinders containing compressed flammable gases were estimated on the basis of the PN-N-18002:2011 standard. Under this standard, occupational risks associated with any identified workplace hazards can be assessed by determining the likelihood of the consequences of such hazards which can affect the life and health of personnel, and the severity of such consequences. Using risk matrix as the risk-assessment method, it was established that during firefighting and rescue operations explosions of tanks/cylinders with industrial gases are likely, and their consequences for firefighters are moderate or serious. On this basis, the explosion of a tank/cylinder containing compressed flammable gas, as a risk for firefighters at work, was assessed as moderate or serious (based on the severity of the explosion’s consequences). Conclusions: Moderate risk is treated as acceptable, while serious risk as unacceptable. Both these risk levels require the appropriate measures to be taken in order to reduce occupational-risk levels (both by reducing the likelihood of such incidents as the explosion of a tank/cylinder with a compressed flammable gas, and by using firefighter protection to cushion the effects of the explosion).

Authors and Affiliations

Marek Woliński, Marzena Półka, Bożena Kukfisz

Keywords

Related Articles

The Stochastic Nature of the Fire Evacuation of People from Buildings

Aim: The purpose of this article is to present the stochastic nature of the process of evacuating people from buildings. This process depends on the behaviour of the group of evacuees, as well as the speed of their movem...

Dostępność przestrzenna straży pożarnej do miejsc potencjalnych interwencji na terenie województwa łódzkiego

Cel: Głównym celem analizy jest określenie przestrzennego dopasowania lokalizacji i rangi jednostek straży pożarnej do rozmieszczenia ludności, elementów zagospodarowania terenu i ukształtowania środowiska województwa łó...

Zwiększenie skuteczności gaszenia pożarów metodą gazową z wykorzystaniem fali uderzeniowej

Cel: Określenie parametrów mających na celu zwiększenie skuteczności gaśniczej CO2 i N2 oraz mocy fali uderzeniowej przy ich jednoczesnym zastosowaniu do gaszenia płomienia dyfuzyjnego n-heptanu C7 H16. Określenie właś...

Zastosowanie numerycznej mechaniki płynów CFD do modelowania zabezpieczania pomieszczeń stałymi urządzeniami gaśniczymi gazowymi

Cel: W artykule podjęto problem bezpieczeństwa pożarowego pomieszczeń chronionych instalacją stałych urządzeń gaśniczych gazowych. Zwiększenie precyzji i wiarygodności modelowania procesu gaszenia gazem gaśniczym można o...

Miarodajna gęstość obciążenia ogniowego strefy pożarowej – wartość nominalna z pojedynczej inwentaryzacji czy raczej statystycznie uzasadniona wartość charakterystyczna

Cel: Przedstawiono dwa alternatywne podejścia do specyfikacji miarodajnej wartości gęstości obciążenia ogniowego strefy pożarowej. Gęstość ta zależy od nagromadzonych w rozpatrywanej strefie materiałów palnych i determin...

Download PDF file
  • EP ID EP265259
  • DOI 10.12845/bitp.48.4.2017.4
  • Views 81
  • Downloads 0

How To Cite

Marek Woliński, Marzena Półka, Bożena Kukfisz (2017). The Explosion of Tanks Containing Compressed Flammable Gas as a Risk for Firefighters at Work. Safety & Fire Technology, 48(48), 70-78. https://www.europub.co.uk/articles/-A-265259