The Influence of Composite Resin Type and Light Curing Source on the Microleakage of Composite Restorations

Journal Title: Acta Facultatis Medicae Naissensis - Year 2018, Vol 34, Issue 4

Abstract

The aim of this study was to evaluate the influence of composite resin type and light curing source on the microleakage of composite restorations. The material consisted of 48 Class V cavities prepared on 24 extracted human premolars. The cavities were divided into two groups (n = 24), depending on the applied composite resin (flowable Filtek Ultimate vs universal Valux Plus). The division into two subgroups (n = 12) was dependent on the used light curing source (halogen ESPE Elipar Highlight vs LED Twinlex Blue Lex). The evaluation of composite restorations microleakage was performed using the dye penetration method with 1% methylene blue solution. The dye penetration was assessed after the longitudinal cut of the teeth. It was ranked according to the scale of 0-4. The highest microleakage score was in the group with flowable composite and halogen light (2.92 ± 1.16), and the lowest in the group with universal composite and LED light (0.75 ± 1.36). Mann-Whitney test showed that there was a statistically significant difference in the composite restorations microleakage between the following groups: flowable/halogen vs universal/halogen, flowable/LED vs universal/LED and flowable/halogen vs univer-sal/LED (p < 0.05). It can be concluded that the influence of composite resin type on composite restorations microleakage is higher than of the light curing source.

Authors and Affiliations

Stefan Dačić, Tamara Karuntanović, Nikola Miljković, Milica Dačić, Dragica Dačić-Simonović, Aleksandar Mitić

Keywords

Related Articles

QALY - MEASURE OF COST-BENEFIT ANALYSIS OF HEALTH INTERVENTIONS

For the purpose of economic evaluation in the health economics, several analytical techniques that are designed for comparing two or more health interventions in terms of costs and effects are used. Cost-benefit analysis...

PREOPERATIVNA PRIPREMA BOLESNICA ZA GINEKOLOŠKE OPERACIJE

Za operativno lečenje bolesnice obolele od ginekološke bolesti odlučujmo se nakon što su iscrpljene sve mogućnosti konzervativnog lečenja. Operativno lečenje predstavlja stres za bolesnicu, a rizici i komplikacije koje o...

NEW MARKERS IN PROGNOSIS OF SEVERE COMMUNITY - ACQUIRED PNEUMONIA

Community-acquired pneumonia (CAP) is the most common cause of death among infectious diseases. During the management of pneumonia, it is often uncertain when the disease may turn into severe form. The first definition o...

Developmentand Validation of a Questionnaire about Patient Knowledge of Adverse Effects of Statins - - - Dizajn i validacija upitnika za procenu znanja bolesnika o neželjenim dejstvima statina

Statins are drugs that are well tolerated, but considering their extensive use, there are still concerns regarding their safety. Knowledge of patients about the side effects of statins has not been adequately studied, al...

COMPARATIVE INVESTIGATIONS OF THE INCIDENCE OF SEXUAL ASSAULT IN THREE REGIONS OF THE REPUBLIC OF BULGARIA DURING 1997-2006

Sexual abuse is considered as a crime against the person all over the world. Despite the age of victims, it could trigger serious physical and psychological consequences, psychoactive substances and drug abuse, reproduct...

Download PDF file
  • EP ID EP422408
  • DOI 10.2478/afmnai-2018-0036
  • Views 116
  • Downloads 0

How To Cite

Stefan Dačić, Tamara Karuntanović, Nikola Miljković, Milica Dačić, Dragica Dačić-Simonović, Aleksandar Mitić (2018). The Influence of Composite Resin Type and Light Curing Source on the Microleakage of Composite Restorations. Acta Facultatis Medicae Naissensis, 34(4), 337-344. https://www.europub.co.uk/articles/-A-422408