THE SOURCE OF ERRORS IN THE OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS
Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 4
Abstract
This report presents an analysis of the source of errors in the blood pressure measurements which use the oscillometric method. The basis of this method are the blood pressure oscillations in the occluding cuff which are used to evaluate systolic and diastolic pressures. They are found during calculations with the use of fixed constants. These numbers, having a statistical meaning, are the main source of a measuring error. The respective theoretical considerations are presented. Here they have been confirmed by the example of comparison of the measuring results obtained from two different blood pressure devices. During tests the instruments were connected together to the same occluding cuff A statistical method was used for evaluation of the results: the coefficient of variation and the reliability coefficient.
Authors and Affiliations
BARBARA JUROSZEK
DATA FUSION APPLICATIONS IN THE TRAFFIC PARAMETERS MEASUREMENT
In the paper the problem of measuring road traffic parameters using systems with complex algorithms for measurement data processing is discussed. A characteristic feature of these systems is utilising there data fusion m...
FOUR-PARAMETER SINE-FITTING ALGORITHM FOR DETECTION AND CLASSIFICATION OF TRANSIENTS AND WAVEFORM DISTORTIONS
This paper describes a new method for detection of some power quality (PQ) disturbances, namely transients and waveform distortions. The proposed algorithm is based on a modified version of the four-parameter sine-fitti...
DIGITAL-TO-ANALOG CONVERSION USING DELTA-SIGMA MODULATORS IMPLEMENTED IN VIRTEX-4 FPGA DEVICES
This paper presents some selected architectures of delta-sigma modulators which are suitable for implementation of digital-to-analog converters (DACs) in modern FPGA devices. Simulation and implementation of simple archi...
A TRANSDUCER INTERFACE FOR RESISTIVE SENSOR ELEMENTS BASED ON THE USE OF A FLIP-FLOP<br />
This paper presents a new transducer interface. This interface serves the resistive bridges. The A/D conversion is based on the use of an auto-compensatory system with two digital-to-analog converters (DACs). A new measu...
RESEARCH ON HYSTERESIS OF TRIGGERING PROBES APPLIED IN COORDINATE MEASURING MACHINES
The article presents selected results of investigation of triggering probe hysteresis in coordinate measuring machines. The research covered the hysteresis of pretravel of one-stage triggering probes equipped with a swit...