Abstract

Horizontal conductors used for distribution of electrical power generate magnetic fields around the vicinity of the conductors due to the flow of current. In the absence of a well calibrated magnetometer, theoretical estimation of the magnitude of the magnetic flux density around these power lines is possible and recommendable. In this study, we calculated the magnetic field exposure from extremely low frequency magnetic field around 11 kV power distribution lines at Rukpokwu, Rivers State, Nigeria using theoretical and mathematical formulations. 32 sample points were considered at horizontal distances of between 1 m and 1000 m from the foot of the vertical pole subtending the electrical conductors. We used a mathematical software (Wolfram Mathematica 8.0) to generate the initial results of the magnetic field current coefficients (Icoef) for the vertical and horizontal components of the magnetic fields and the total magnetic fields for x=1 to 1000 m (horizontal distance from the foot of the pole) for a vertical height of 1 m above the ground surface (considered to be the average height of head positions of the workers and the public within the vicinity of magnetic field). The results showed that for horizontal distances of between 1 and 10 m, the magnetic field exposures ranged from 45.82 μT/hr to 21.62 μT/hr and are above the occupational field exposure limit of 21.0 μT/hr set by International Committee on Non Ionizing Radiation Protection (ICNRIP). Also, the results of field exposure for horizontal distances ranging from 1 to 20 m were between 45.82 μT/hr and 8.3 μT/hr and are above the ICNRIP limit of 4.2 μT/hr set for the public. It is recommended that between horizontal distances of 1 and 10 metres from the distribution lines, relevant government agencies and the populace should discourage the building of shops for businesses, and between the horizontal distances of 1 to 20 metres, they should discourage the building of residential areas, since doing business and residing within these stipulated distances may not be very safe as a result of the magnetic field exposure.

Authors and Affiliations

P. I. Enyinna, A. N. Orlunta

Keywords

Related Articles

A Geophysical Investigation of a Solid Waste Landfill Using Vertical Electrical Sounding Method in Aluu Community, Rivers State, Nigeria

Vertical electrical sounding was conducted at a solid waste landfill in Aluu community for a hydro-geophysical assessment of the contamination of soil and groundwater. The ABEM Terrameter employing the Schlumberger array...

Evaluation of Radiation Doses from Paediatric Chest X-ray Examination at Three Hospitals in South-West Nigeria

The aim of this study is essentially to evaluate radiation doses to paediatric patients who were referred for chest X-ray examination between April, 2015 and December, 2016 in three hospitals South-West, Nigeria. The met...

Mesoscopic RLC Circuit and Its Associated Occupation Number and Berry Phase

In this paper we consider the quantization of the time-dependent harmonic oscillator and its associated Berry phase using the invariant operator method, as well as the occupation number of the induced quasi-particle prod...

Coal-fired Power Plants and Their Impact on Ecosystems Health

Coal-fired power plants emit greenhouse gases (GHG) that cause global warming. Coal, being one of the most important fossil fuel, emits three times as much GHG as natural gas. The combustion of coal (fossil fuels at larg...

Investigation of Field Induced Effect of High Voltage Transmission Line in Calabar South, Nigeria

Due to increase in energy cost of transmission, high voltage transmission becomes the most economical for the transfer of large amounts of electrical power, because the higher the transmission voltage, the more efficient...

Download PDF file
  • EP ID EP321143
  • DOI 10.9734/PSIJ/2017/30035
  • Views 70
  • Downloads 0

How To Cite

P. I. Enyinna, A. N. Orlunta (2017). Theoretical Computation of Magnetic Flux Density within the Vicinity of Rukpokwu 11 KV Distribution Power Lines. Physical Science International Journal, 13(3), 1-11. https://www.europub.co.uk/articles/-A-321143