Trunk Kinematic Analysis during Gait in Cerebral Palsy Children with Crouch Gait Pattern
Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 3
Abstract
Background: Deficits in upper body movement have received little attention during gait in cerebral palsy (CP) children with crouch gait pattern (CGP). Objective: Purpose of this research is to describe the correlation of trunk movement with the excessive knee flexion and ankle kinematic in CP children with CGP. Material and Methods: Gait analysis data from 57 limbs of diplegic CP children with CGP and 26 limbs of normal children was gathered. Kinematic parameters of trunk in relation to the pelvis were extracted in the sagittal, transverse and coronal planes. CP limbs were clustered using K-means cluster analysis according to the knee flexion angle at initial contact and the mean position of ankle joint during the stance phase of gait cycle, to three clusters. Pearson correlation coefficient between knee, ankle and trunk kinematic variables was assessed. Differences between clusters were analyzed with Kruskal–Wallis and post hoc tests. Results: The results revealed: 1) crouch clusters had more trunk obliquity and rotation mean position than normal; 2) the range of motions of the trunk obliquity and rotation exhibited significant differences between crouch and normal clusters; 3) the level of excessive knee flexion had positive correlation with the trunk mean position in all planes; 4) the ankle kinematic at stance phase was associated with the trunk mean position in all planes. Conclusion: The results revealed the trunk mean position is correlated with the excessive knee flexion severity and ankle joint kinematic in CP children with CGP.
Authors and Affiliations
L. Abbasi, Z. Rojhani-Shirazi, M. Razeghi, H. Raeisi Shahraki
Optimization of Brain Tumor MR Image Classification Accuracy Using Optimal Threshold, PCA and Training ANFIS with Different Repetitions
Background: One of the leading causes of death is brain tumors. Accurate tumor classification leads to appropriate decision making and providing the most efficient treatment to the patients. This study aims to optimize b...
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characteriza...
A Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film
Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient....
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated. Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. M...
Why Should We Have a Periodic Safety and Performance Program for Medical Devices
Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance...