VENTILATION IN FLAT

Abstract

The paper focuses on the natural ventilation research of space through windows. The various ventilation strategies were examined in relation to the number of open windows and ventilation geometry ergo air flow distribution. The numbers of chosen air flow distributions in space are 2. The first air distribution flow presents a simple ventilation distribution with one open window and the second is cross ventilation by 2 windows on opposite sides of the building envelope. The measurements were performed for the purpose of monitoring of carbon dioxide (CO2) concentration decreasing, which is on value level over 1200 ppm, to value level of 500 ppm up to 530ppm in relation to speed of decline, thus a time duration of ventilation. The level of CO2 concentration exceeding the value 1200 ppm represents values, which do not meet Code requirements of European standards STN EN 15251 and STN EN 13779. The considered CO2 concentrations of 500 ppm up to 530 ppm meet first category of European standards STN 15251 and also represent values at about 100 ppm above background outside CO2 concentration. The measurements were performed by using of Testo 435 instrument and took 4 days. The aim of the measurements was to determine the simple but effective strategy of ventilation for the operation of the apartment space and to achieve the Code values of CO2 concentration and thus for the purpose the indoor air quality improving.

Authors and Affiliations

R. Nagy

Keywords

Related Articles

ANALYSIS OF THERMAL PROPERTIES OF FLOORS IN HEATED BUILDINGS

The article discusses some thermal properties of floors and floorings, such as heat transfer and heat absorption. It was pointed out that there are no specific requirements in the field of heat absorption by floor constr...

Моделювання процесів теплообміну в топках водотрубних котлів дКВР(де)-10/14

Тhe results of a numerical study of heat transfer in water-tube boiler DKVR(DE)-10/14 furnace are provided. The geometric model of the inner cavity of furnaces and burners is constructed with help of boiler and burner GM...

НАНОМОДИФІКОВАНІ ШВИДКОТВЕРДНУЧІ БЕТОНИ, АРМОВАНІ ДИСПЕРСНИМИ ВОЛОКНАМИ

It is shown that one of the innovative ways of obtaining of Rapid-hardening concretes with enhanced performance for fortifications is the use of nanotechnology techniques related to the directed process of structure form...

ОСНОВНІ СТОХАСТИЧНІ ПАРАМЕТРИ ПРИ ОЦІНЮВАННІ НАДІЙНОСТІ ЗАЛІЗОБЕТОННИХ БАЛОК, ПІДСИЛЕНИХ ДОДАТКОВИМ АРМУВАННЯМ

Today there are many scientific and technical knowledge that make construction a reliable, fast and economical. To provides a safe and durable (the fundamental components of reliability) of builnings and structures are d...

ДОСЛІДЖЕННЯ НЕСТАЦІОНАРНИХ НАПІРНИХ ТЕЧІЙ У ТРУБАХ НА ОСНОВІ МАТЕМАТИЧНИХ МОДЕЛЕЙ

The article deals with mathematical modeling of non-stationary processes non-periodic pressure of the fluid in cylindrical tubes. Based on the Navier-Stokes equations for compressible fluid withdrawn simplified equation...

Download PDF file
  • EP ID EP284788
  • DOI -
  • Views 129
  • Downloads 0

How To Cite

R. Nagy (2017). VENTILATION IN FLAT. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(877), 261-265. https://www.europub.co.uk/articles/-A-284788