Analysis on testing ability of blood testing laboratories in domestic blood establishments across China

Journal Title: Chinese Journal of Blood Transfusion - Year 2022, Vol 35, Issue 7

Abstract

Objective To analyze testing ability of blood testing laboratories in domestic blood establishments, and to comprehensively understand the resource allocation, workload and unqualified blood samples. Methods All blood testing laboratories reported the quarterly quality indicator data via their EQA system on the website of National Center for Clinical Laboratories (https: //srv.clinet.cn/qblood/report/add1.aspx). We collected related quality indicators throughout 2020, including resource indicators, number of sample detection, and number (rate) of unqualified samples. All the data were integrated by EQA system. Results 1) Throughout 2020, 324 blood testing laboratories reported that 13 529 778 donations were tested by immunoassays and 13 892 927 donations were tested by nucleic acid testing(NAT). Among them, 253 laboratories reported the data correctly throughout four quarters, and they tested 12 015 407 donations. 2) The number of equipment varied greatly among different laboratories, and a certain equipment was often overloaded in some laboratories. 3) The proportion of domestic ELISA reagents was 100% (322/322), while the proportion of imported NAT reagents was 75.33% (220/300). 4) The positive rate of HBsAg was closely related to geographical locations, as Sichuan (0.86%, 5 895/689 445), Guangdong (0.57%, 5 147/895 929), and Guangxi (0.53%, 3 021/573 216) provinces demonstrated higher positive rates than that of other provincial regions. Conclusions There are many blood stations across China, with great differences in scale and equipment. There are obvious differences in the positive rates of infectious indicators in different regions. Therefore, the laboratory should make horizontal comparison with the laboratories in the same region, to improve the detection quality of the laboratory in time and effectively.

Authors and Affiliations

Le CHANG, Ying YAN, Huimin JI, Lunan WANG

Keywords

Related Articles

Identification and test methods of rare unexpected antibodies in grassroots medical institutions

Objective To explore how to identify rare unexpected antibodies using routine serology methods in blood transfusion department of grassroots hospitals. Methods A patient with gastrointestinal bleeding with inconsistent f...

Discussion on the construction of holistic nursing based on SWOT in apheresis platelets collection

Objective To explore the application and effectiveness of holistic nursing based on SWOT in platelet collection at blood stations. Methods SWOT analysis was used to analyze the causes of adverse reactions to blood donati...

Efficacy of apheresis and concentrated platelets under different transfusion strategies

Objective To retrospectively analyze the clinical effects of apheresis and concentrated platelets under different transfusion strategies, so as to explore more scientific transfusion strategies. Methods A total of 279 pa...

Comparison of yield of microorganisms in cord blood between two automated blood culture systems

Objective To compare the difference in the detection rate of microorganisms in cord blood between BACTEC FX and BacT/ALERT 3D automated blood culture systems, and to compare the influence of incubation time and different...

Enhancing the sensitivity of HIV DNA detection: a magnetic bead-based method

Objective To establish a magnetic bead enrichment strategy for the detection of human immunodeficiency virus deoxyribonucleic acid (HIV DNA) in peripheral blood, and to verify the improvement of the sensitivity of this m...