Development and validation of HPLC/UV-procedures of secnidazole determination in blood and urine

Journal Title: ScienceRise: Pharmaceutical Science - Year 2018, Vol 0, Issue 6

Abstract

<p><strong>Aim. </strong>The system of HPLC-analyzer MiLiChrome® A-02 is widely used in Ukrainian laboratories of forensic toxicology. The purpose is to apply the HPLC-analyzer system for secnidazole quantitative determination in biological liquids and carry out validation of the developed procedures.</p><p><strong>Methods.</strong> Sample preparation of blood and urine was carried out in three ways – 1) liquid-liquid extraction with organic solvents immiscible with water, 2) amphiphylic solvents extraction and salting-out with ammonium sulphate, 3) complex application of liquid-liquid extraction with organic solvents immiscible with water and amphiphylic solvents extraction with salting-out. Chromatographic conditions: column – Æ2´75 mm, ProntoSIL 120-5-C18 AQ, 5 μm; temperature – 40°С; flow rate – 100 μl/min; Eluent A – 0.2 M LiClO<sub>4</sub> – 0.005 M HClO<sub>4</sub>; Eluent B – acetonitrile; elution mode – linear gradient; detection – UV, 277 nm; volume of injection – 2 μl.</p><p><strong>Results. </strong>Validation of all developed procedures has been carried out by such parameters as specificity, recovery, linearity, accuracy and precision in the variant of the method of standard. The results of analysis have shown the absence of peaks with the retention time, which is coincident with the secnidazole retention time, on the chromatograms of blank-samples for all variants of procedures of analyte isolation. All procedures of sample preparation show the high efficiency of secnidazole isolation both for blood and urine (at the level of 90 %). All examined procedures are characterized by the acceptable parameters of linearity, within-run and between-run accuracy and precision.</p><p><strong>Conclusions. </strong>The set of HPLC-procedures of secnidazole quantitative determination in blood and urine has been developed. Validation of the developed procedures has been carried out; isopropanol application in the acid medium is optimal for biological liquids sample preparation</p>

Authors and Affiliations

Oksana Shovkova, Lina Klimenko, Zoia Shovkova, Olena Mykytenko

Keywords

Related Articles

Current state assessment of pharmaceutical care implementation in Ukraine

<p>At the modern stage of the pharmacy development, there were significant changes in the positioning of the pharmacist’s role in the health care system. It has contributed to the development of pharmaceutical care (PC)...

Investigations with the aim of obtaining a mass for pressing medicated chewing gums "Lysodent C"

<p>The design of high quality compressed medicated chewing gum "Lysodent C" with lysozyme hydrochloride and ascorbic acid as active pharmaceutical ingredients and the composition Health in Gum<sup>®</sup> PWD-01 as a che...

Експериментальне визначення спектру протисудомної дії нових похідних піразоло[3,4-D]піримідин-4-ону

<p><strong>Мета.</strong> Визначити діапазон ефективних доз трьох нових похідних піразоло[3,4-d]піримідин-4-ону на базовій моделі пентилентетразолових судом та спектр антиконвульсивної дії на експериментальних моделях су...

Influence of extract of peach ordinary (persica vulgaris) leaves on the state of thymic-lymphatic element of the immune system of rats in conditions of chronic immobilization stress

<p><strong>The aim</strong> – study of the influence of thick extract of peach ordinary (Persica vulgaris) leaves (TEPL) on the state of thymic-lymphatic element of the immune system of rats in conditions of chronic immo...

Investigation of food supplements with preservative e211 (sodium benzoate) using thin-layer chromatography

<p>Sodium benzoate is often chosen for the manufacture of liquid food supplements as preservative due to its antimicrobial effect against a large number of microorganisms. Permissible sodium benzoate amount in liquid foo...

Download PDF file
  • EP ID EP526864
  • DOI 10.15587/2519-4852.2018.153035
  • Views 172
  • Downloads 0

How To Cite

Oksana Shovkova, Lina Klimenko, Zoia Shovkova, Olena Mykytenko (2018). Development and validation of HPLC/UV-procedures of secnidazole determination in blood and urine. ScienceRise: Pharmaceutical Science, 0(6), 26-34. https://www.europub.co.uk/articles/-A-526864