EVALUATION OF THE BOTTOM SURFACE WATER JET IMPINGEMENT COOLING RATE USING MODIFIED RUN-OUT TABLE

Journal Title: Engineering and Technology Journal - Year 2022, Vol 7, Issue 11

Abstract

Evaluation of Temperature-Time Profiles by the Lumped Thermal Mass analysis method for bottom surface jet impingement cooling system was carried out. This was done by controlled accelerated cooling using a modified run-out table (ROT). The evaluation was with variant pipe diameters of 10mm - 40mm by a single water jet, having impingement gaps in the range of 55mm - 95mm and controlled sub-cooled to a range of 150oC – 110oC. The results revealed that the cooling rate was faster at an impingement gap of 95mm in all the pipe diameters. This was evident from the plot of temperature-time, with a gap of 95mm showing 1.93oC/s and 3.24oC/s at diameters of 10mm and 40mm respectively. This evidently revealed that at any given pipe diameter the cooling rate is higher at a higher impingement gap for bottom surface controlled cooling. This is also suggested by the calculated heat transfer coefficient that shows an increase with the increase in pipe diameter and impingement gap for an increase in cooling rate. Therefore, for bottom surface jet impingement cooling, a higher impingement gap for any pipe diameter will give a better cooling rate for the steel austempering process.

Authors and Affiliations

Azubuike Michael Nwankwo   Emeka Augustine Chinachi   Ifeanyi C. C. Iloabachie

Keywords

Related Articles

UTILIZATION OF CASSAVA TUBERS (DIOSCOREA ALATA) AND CHITOSAN TO PRODUCE BIODEGRADABLE PLASTIC

Plastic is a synthetic compound made from petroleum, which is very useful for various household and industrial purposes. This is due to the many superior properties of plastic compared to other materials. However, on the...

Optimization of Turning Process Performance Characteristics during Machining of AISI 304 Material

Turning process variables significantly affect the turning process performance. In the present work, Taguchi technique was applied to optimize the turning process performance during machining of AISI 304 material under c...

A CASE STUDY OF INDUSTRIAL CONTROL SYSTEM NETWORK SECURITY

This case study presented the design of an Industrial Control System (ICS). The design focused on network security using network segmentation and redundancy. The objective was to relate theoretical network defense stra...

Solar Power Plant Design Using Automatic Transfer Switch on PLN-PLTS Network

Solar power plants are conventional generators, solar power is often in demand by the public in general, but the use of solar power plants experiences several problems, such as batteries that are easily damaged. This is...

AVAILABILITY AND RELIABILITY INDICES: A PRACTICAL APPROACH FOR AFAM THERMAL PLANT ASSESSMENT AND IMPROVEMENT

Mechanical integrity and risk analysis for power stations are often based on few failure data. The risk issue is to reduce and forecast future failure and corrective actions taken to mitigate down time. The power station...

Download PDF file
  • EP ID EP717185
  • DOI 10.47191/etj/v7i11.06
  • Views 72
  • Downloads 0

How To Cite

Azubuike Michael Nwankwo   Emeka Augustine Chinachi   Ifeanyi C. C. Iloabachie (2022). EVALUATION OF THE BOTTOM SURFACE WATER JET IMPINGEMENT COOLING RATE USING MODIFIED RUN-OUT TABLE. Engineering and Technology Journal, 7(11), -. https://www.europub.co.uk/articles/-A-717185