Evaluation of the Performance of Neutral Oral Contrast Materials: A Computered Tomography Enterography Study

Journal Title: Journal of Ankara University Faculty of Medicine - Year 2021, Vol 74, Issue 1

Abstract

Objectives: We aimed to compare the performances of two neutral oral contrast agents, polyethylene glycol (PEG) and lactulose solution. Materials and Methods: The computed tomography enterography (CT-E) data of 54 consecutive patients that either used lactulose solution or PEG were retrospectively analyzed and measurements were made by the mutual agreement of 2 radiologists. The radiological records of patients were also evaluated by including technician’s notes regarding patient compliance with instructions and a questionnaire to be filled out by the patients about oral contrast agent related discomfort. The intestinal distension and patient’s tolerance were compared between the lactulose solution and PEG groups. The relationship between the lactulose solution and PEG groups was analyzed using the Student’s t-test for continuous variables with normal distribution, and the Mann-Whitney U test for continuous variables without normal distribution. The relationship between the lactulose group and the PEG group in terms of patient tolerance was evaluated using the chi-square test. Results: The intestinal distention provided by the lactulose group in the duodenal segments was superior to that of the PEG group (p<0.001). We observed no significant difference in the jejunum and ileum between two oral contrast agents (p=0.747 and p=0.662). Lactulose was better tolerated when compared to PEG (likelihood ratio=7.38, p=0.025). Conclusion: Lactulose is the preferred oral contrast agent for CT-E studies due to its achievement in duodenal distension and its better tolerance.

Authors and Affiliations

Aslıhan Onay Çolak, Barış Bakır

Keywords

Related Articles

Has Minimal Invasive Surgery Caused Alterations in Open Surgical Techniques?

Objectives: Some of the methods, which were routinely used in traditional open surgical techniques, have vanished nowadays as a result of technical and technological improvements. The aim of this study is to interrogate...

Case Report and Review of Literature: Patient with Malignant Pheochromocytoma

Pheochromocytomas are catecholamine-secreting neuroendocrine tumors that arise from chromaffin cells of the adrenal medulla. At least 10 percent of pheochromocytomas are malignant. A diagnosis of malignant pheochromocyto...

Evaluation of Circulatory System Disease Codes in the Transition Process to the Eleventh Revision of the International Classification of Diseases

The International Classification of Diseases (ICD) contributes to the issue of registration of illnesses as accurate as possible in the determination of illness identification or death cause through the international rul...

Direct and Indirect Cost Analysis for Emergency Department Patients

Objectives: To determine the use of resources and workforce in the actual procedure time of the patient in the emergency department (ED), and to determine the total costs according to the triage levels and the factors af...

Investigation of The Relationship Between Congenital Hypothyroidism and Respiratory Distress Syndrome in Very Low Birth Weight Newborns

Objectives: Respiratory distress syndrome (RDS) is associated with severe morbidity and mortality, which occurs due to surfactant deficiency in the lung. In the present study, we aimed to determine the risk factors for R...

Download PDF file
  • EP ID EP694401
  • DOI 10.4274/atfm.galenos.2020.43660
  • Views 98
  • Downloads 0

How To Cite

Aslıhan Onay Çolak, Barış Bakır (2021). Evaluation of the Performance of Neutral Oral Contrast Materials: A Computered Tomography Enterography Study. Journal of Ankara University Faculty of Medicine, 74(1), -. https://www.europub.co.uk/articles/-A-694401