Firefighting Water-supply System Requirements – a Critical Assessment

Journal Title: Safety & Fire Technology - Year 2017, Vol 48, Issue 48

Abstract

Aim: This paper is an attempt to interpret selected current requirements concerning the capacity of firefighting water supply networks. It points out inaccuracies which can cause difficulties in decision-making at the design stage and hinder the process of project coordination. The purpose of the paper is to initiate a discussion leading to appropriate legal changes. Introduction: The design of a water supply system with fire hydrants needs to be agreed on with a fire surveyor. However, the designer is not released from responsibility for the solutions used in the design. The binding requirements set out in the Minister of the Interior and Administration Regulation of 24 July 2009 on Fire-Fighting Water Supply and Fire Access Roads might cause interpretation issues regarding the capacity of water supply systems, the conditions for testing hydrant flow rates and the rules for selecting pipe diameters. Methodology: The paper presents an analysis of the existing regulations concerning the capacity of firefighting water supply systems for settlements. It addresses the problem of ambiguity related to the requirement for simultaneous water use from two adjacent fire hydrants for water supply systems with a total water demand exceeding 20 l/s. In this context, the paper attempts to interpret the Regulation governing the required flow rate of each of the two adjacent hydrants. Moreover, it draws attention to the need for clarifying for which structures the capacity of water supply systems used not only for fire protection can be calculated on the basis of reduced capacity for household and industrial purposes. In order to resolve these issues, the paper takes into consideration historical regulations underlying the mentioned Regulation. Conclusions: The existing Regulation contains a number of inaccuracies which make its interpretation difficult. Some of its provisions have lost their original meaning as a result of multiple amendments. Hence, it is necessary to introduce appropriate amendments to resolve the ambiguities. Over the past few years, the numerical modelling of water supply systems has come into wide use. Among other things, it allows the analysis of how water supply systems operate when used for firefighting purposes. Such analysis should be considered a measure to assess the capacity of firefighting water supply systems and facilitate the choice of pipeline diameters.

Authors and Affiliations

Grzegorz Ścieranka

Keywords

Related Articles

New Requirements for Smoke Alarm Devices

Objective: The objective of this article is to present delays in the standardisation of smoke alarm devices in relation to the present technological advancement of such devices, and to identify errors and irregularities...

Zastosowanie silikonów w ochronie przeciwpożarowej

Cel: Omówienie możliwości zastosowania w ochronie przeciwpożarowej polimerów silikonowych jako materiałów o unikalnych właściwościach. Wprowadzenie: Szczególne właściwości polimerów silikonowych związane są z synergią od...

Long-Term Variability of Forest Fires in Selected 28 European Countries, Canada and the USA

Aim: The primary aim of this paper was to determine long-term variability in the number of forest fires and burnt forest area in selected 28 European countries, Canada and the USA and to assess the effectiveness of fir...

The Impact of the Fire Source Location on Fire Development in a Large-Space Steel Commercial Building

Aim: The aim of this paper is to show that fire development in a large-space steel commercial building may have a different intensity depending on the location in which the fire originated. Buildings of this type are u...

Extinguishment of N-heptane Diffusion Flames with the Shock Wave

Objective: To determine the effectiveness of extinguishing diffusion flames of n-heptane with a shock wave (SW). Establishing a possible mechanism of suppression of diffusion flame with a shock wave on n-heptane С7Н16 fl...

Download PDF file
  • EP ID EP265311
  • DOI 10.12845/bitp.48.4.2017.9
  • Views 75
  • Downloads 0

How To Cite

Grzegorz Ścieranka (2017). Firefighting Water-supply System Requirements – a Critical Assessment. Safety & Fire Technology, 48(48), 124-136. https://www.europub.co.uk/articles/-A-265311