Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation

Abstract

To meet with the ever-enhancing load demands, new transmission lines should be bolted-on in the existing power system but the economic and environmental concerns are major constraints to this addition. Hence utilities have to rely on the existent power system infrastructure with some modifications. To enhance controllability and boost power transfer potential of the existing power system the use of Flexible Alternating Current Transmission System (FACTS) device is the most viable modification. FACTS devices include Static VAR Compensator (SVC), thyristor controlled series capacitor (TCSC), Thyristor Controlled Reactor (TCR), Thyristor Switched Capacitor (TSC) and Self Commutated VAR compensators i.e. Static Synchronous Compensator (DSTATCOM). Among the FACTS devices, DSTATCOM is the most feasible choice because of its capability to furnish both leading and lagging reactive power, faster response time in comparison with others, smaller harmonic content, inrush current generation is minimum and the dynamic performance with variations of voltage is quite good. DSTATCOM has the ability to have effective control over various issues concerning AC power transmission. However, the Parameters of the protection devices in the present power system are set without taking into account the reaction of these FACTS devices. So in order to ascertain stability and reliability of power system, reaction of FACTS devices with the existent protection schemes must be thoroughly investigated. This paper aims to explore the deviations in the performance characteristics of transmission line protection due to installation of DSTATCOM on a 220KV EHV transmission line using theoretical as well as MATLAB/SIMULINK simulation models. The dynamic performance of a DSTATCOM connected to an existing transmission line system is evaluated when large industrial induction motor is started and voltage sags are introduced.

Authors and Affiliations

Yasar Khan, Khalid Mahmood, Sanaullah Ahmad

Keywords

Related Articles

Evolutionary Design of a Carbon Dioxide Emission Prediction Model using Genetic Programming

Weather pollution is considered as one of the most important, dangerous problem that affects our life and the society security from the different sides. The global warming problem affecting the atmosphere is related to t...

Hierarchical Compressed Sensing for Cluster Based Wireless Sensor Networks

Data transmission consumes significant amount of energy in large scale wireless sensor networks (WSNs). In such an environment, reducing the in-network communication and distributing the load evenly over the network can...

 Data normalization and integration in Robotic Systems using Web Services Technologies

 The robotics is one of the most active areas. We also need to join a large number of disciplines to create robots. With these premises, one problem is the management of information from multiple heterogeneous sourc...

Iterative Removing Salt and Pepper Noise based on Neighbourhood Information

Denoising images is a classical problem in low-level computer vision. In this paper, we propose an algorithm which can remove iteratively salt and pepper noise based on neighbourhood while preserving details. First, we c...

Improving Accelerometer-Based Activity Recognition by Using Ensemble of Classifiers

In line with the increasing use of sensors and health application, there are huge efforts on processing of collected data to extract valuable information such as accelerometer data. This study will propose activity recog...

Download PDF file
  • EP ID EP260005
  • DOI 10.14569/IJACSA.2017.080812
  • Views 68
  • Downloads 0

How To Cite

Yasar Khan, Khalid Mahmood, Sanaullah Ahmad (2017). Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation. International Journal of Advanced Computer Science & Applications, 8(8), 89-99. https://www.europub.co.uk/articles/-A-260005