PHILOS LOCKING PLATES IN PROXIMAL HUMERUS FRACTURES IN OSTEOPOROTIC PATIENTS
Journal Title: International Journal of Pharmaceutical and Biological Sciences Fundamentals (www.ijpbsf.com) - Year 2012, Vol 2, Issue 1
Abstract
Different operative techniques used for treating displaced proximal humeral fractures could result in malunion, non-union, osteonecrosis of humeral head, loosening of screw and loss of reduction particularly in comminuted and osteoporotic fractures. Locking compression plate has been proposed for open reduction and internal fixation of these fractures and is associated with less complication rate. A prospective study was conducted at Department of Orthopedics, MMMC, Mullana Ambala, between July 2005 to July 2008. A total of 20 patients with proximal Humerus Fracture were included in this study. Functional outcome and the complications were assessed after an average follow-up of 14 months. Radio graphically, union was observed in 16 patients at the end of 10 weeks. In three patients, times to union were 16 weeks. One patient underwent autogenous bone grafting because of nonunion after 16 weeks. The mean Constant-Murley score was 82 (range 66-92). Fixation with the Philos plate would be an effective choice in the treatment of complex senile osteoporotic fracture of the proximal humerus.
Authors and Affiliations
Dr Ramji Lal Sahu , Dr Pratiksha Gupta
Patellofemoral Osteoarthritis - Conservative Non-Pharmacological Treatment A Prospective Study
The main purpose of this study was to determine possible pain mechanisms in Patellofemoral osteoarthritic patients and to assess the results of conservative non pharmacological management. A total of 251 patients were...
PHILOS LOCKING PLATES IN PROXIMAL HUMERUS FRACTURES IN OSTEOPOROTIC PATIENTS
Different operative techniques used for treating displaced proximal humeral fractures could result in malunion, non-union, osteonecrosis of humeral head, loosening of screw and loss of reduction particularly in comminut...
SMOKING HABIT AMONG COLLEGE STUDENTS UNDER M.D. UNIVERSITY, ROHTAK, HARYANA -A SURVEY
Adolescent tobacco use and the subsequent health problems are a major concern today. Tobacco consumption has been identified as the single most preventable cause of death and disease in India. Approximately 90% of the Or...
Application of Zinc Oxide Nanoparticles for Fabrication of Biosensor Based on Glucose Oxidase
Nanostructured Zinc oxide (ZnO) is inherently electrocatalytic by nature, thus finding application in the field of enzyme immobilization while also keeping its biological activity undamaged and therefore these nanomateri...
BIO PRODUCTS: THE NEED OF GENERATION
Bio products are very much popular now a day’s. And Bio diesel is one of the important one among these products. Here in this paper author discuss about the bio diesel. The properties, creation and other relevant things...